Model | DR-240-24 | DR-240-48 |
DC output voltage | 24V | 48V |
Output voltage range | ±1% | ±1% |
Rated output current | 10A | 5A |
Output current range | 0-10A | 0-5A |
Wave and noise | 80mVp-p | 150mVp-p |
Inlet stability | ±0.5% | ±0.5% |
Load stability | ±1% | ±1% |
DC output power | 240W | 240W |
Efficiency | 84% | 85% |
Adjustable range for DC voltage | 21.6~26.4V | 43.2~52.8V% |
AC input voltage range | 88~264VAC 47~63Hz;120~370VDC | |
Input current | 3.5A/115V 1.8A/230V | |
AC inrush current | Cold-start current 30A/115V 60A/230V | |
Leakage current | <3.5mA/240VAC | |
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery | |
Over-voltage protection | 30~34V | 54~60V |
High-temperature protection | 100°c±5°c(TSW1) | |
Temperature coefficient | ±0.03%/°c(0~50°c) | |
Setup, rise , hold up time | 800ms, 40ms,20ms/230VAC 800ms, 40ms, 20ms/115VAC | |
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |
Withstand voltage | Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC | |
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ | |
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |
Overall dimension | 125.5×125.2×100mm | |
Weight | 1.2Kgs 20PCS/14Kg/1.1CUFT | |
Safety standards | Meet UL 1012 requiement (Not apply for the mark) | |
EMC standards | Meet FCC PART 15 J Conduction class B | |
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |